T<Tnum>
RepCap Settings
# Range: Nr300 .. Nr319
rc = driver.configure.signaling.nradio.cell.timeout.t.repcap_tnum_get()
driver.configure.signaling.nradio.cell.timeout.t.repcap_tnum_set(repcap.Tnum.Nr300)
SCPI Command :
[CONFigure]:SIGNaling:NRADio:CELL:TOUT:T<no>
- class TCls[source]
T commands group definition. 1 total commands, 0 Subgroups, 1 group commands Repeated Capability: Tnum, default value after init: Tnum.Nr300
- get(cell_name: str, tnum=Tnum.Default) int[source]
# SCPI: [CONFigure]:SIGNaling:NRADio:CELL:TOUT:T<no> value: int = driver.configure.signaling.nradio.cell.timeout.t.get(cell_name = 'abc', tnum = repcap.Tnum.Default) INTRO_CMD_HELP: Configures one of the following timers: - T300, RRC connection establishment - T301, RRC connection re-establishment, after cell selection - T310, detection of radio link failure (out-of-sync) - T311, RRC connection re-establishment, before cell selection - T319, RRC connection resume :param cell_name: No help available :param tnum: optional repeated capability selector. Default value: Nr300 (settable in the interface 'T') :return: timer: Timeout value
- set(cell_name: str, timer: int, tnum=Tnum.Default) None[source]
# SCPI: [CONFigure]:SIGNaling:NRADio:CELL:TOUT:T<no> driver.configure.signaling.nradio.cell.timeout.t.set(cell_name = 'abc', timer = 1, tnum = repcap.Tnum.Default) INTRO_CMD_HELP: Configures one of the following timers: - T300, RRC connection establishment - T301, RRC connection re-establishment, after cell selection - T310, detection of radio link failure (out-of-sync) - T311, RRC connection re-establishment, before cell selection - T319, RRC connection resume :param cell_name: No help available :param timer: Timeout value :param tnum: optional repeated capability selector. Default value: Nr300 (settable in the interface 'T')
Cloning the Group
# Create a clone of the original group, that exists independently
group2 = driver.configure.signaling.nradio.cell.timeout.t.clone()