Scondition

SCPI Command :

[CONFigure]:SIGNaling:MEASurement:BLER:SCONdition
class SconditionCls[source]

Scondition commands group definition. 1 total commands, 0 Subgroups, 1 group commands

class SconditionStruct[source]

Response structure. Fields:

  • Stop_Condition: enums.StopCondition: SAMPles: number of samples reached for at least one cell TIME: measurement duration reached CONFidence: confidence BLER verdict derived

  • Value: float: For SAMPles, number of samples. For TIME, measurement duration. For CONFidence, number of samples applied beyond the maximum value defined by 3GPP (2466 without CA, 1003 per CC with CA) .

get() SconditionStruct[source]
# SCPI: [CONFigure]:SIGNaling:MEASurement:BLER:SCONdition
value: SconditionStruct = driver.configure.signaling.measurement.bler.scondition.get()

Defines a stop condition for single-shot BLER measurements.

return:

structure: for return value, see the help for SconditionStruct structure arguments.

set(stop_condition: StopCondition, value: float = None) None[source]
# SCPI: [CONFigure]:SIGNaling:MEASurement:BLER:SCONdition
driver.configure.signaling.measurement.bler.scondition.set(stop_condition = enums.StopCondition.CONFidence, value = 1.0)

Defines a stop condition for single-shot BLER measurements.

param stop_condition:

SAMPles: number of samples reached for at least one cell TIME: measurement duration reached CONFidence: confidence BLER verdict derived

param value:

For SAMPles, number of samples. For TIME, measurement duration. For CONFidence, number of samples applied beyond the maximum value defined by 3GPP (2466 without CA, 1003 per CC with CA) .