Scondition
SCPI Command :
[CONFigure]:SIGNaling:MEASurement:BLER:SCONdition
- class SconditionCls[source]
Scondition commands group definition. 1 total commands, 0 Subgroups, 1 group commands
- class SconditionStruct[source]
Response structure. Fields:
Stop_Condition: enums.StopCondition: SAMPles: number of samples reached for at least one cell TIME: measurement duration reached CONFidence: confidence BLER verdict derived
Value: float: For SAMPles, number of samples. For TIME, measurement duration. For CONFidence, number of samples applied beyond the maximum value defined by 3GPP (2466 without CA, 1003 per CC with CA) .
- get() SconditionStruct [source]
# SCPI: [CONFigure]:SIGNaling:MEASurement:BLER:SCONdition value: SconditionStruct = driver.configure.signaling.measurement.bler.scondition.get()
Defines a stop condition for single-shot BLER measurements.
- return:
structure: for return value, see the help for SconditionStruct structure arguments.
- set(stop_condition: StopCondition, value: float = None) None [source]
# SCPI: [CONFigure]:SIGNaling:MEASurement:BLER:SCONdition driver.configure.signaling.measurement.bler.scondition.set(stop_condition = enums.StopCondition.CONFidence, value = 1.0)
Defines a stop condition for single-shot BLER measurements.
- param stop_condition:
SAMPles: number of samples reached for at least one cell TIME: measurement duration reached CONFidence: confidence BLER verdict derived
- param value:
For SAMPles, number of samples. For TIME, measurement duration. For CONFidence, number of samples applied beyond the maximum value defined by 3GPP (2466 without CA, 1003 per CC with CA) .